Atomic Absorption Spectrophotometer (AAS) AMT3800 Serials |
Features | |
4. Original "Hg lamp-reagent" gradient measurement. we established an exact mathematical model to estimate "double beam linear and balance" specification. This technology provided a fast and economic method for instrument self testing system. It also established a brand new method to improve instrument's detection performance. 5. Numerous technological innovation and renewal such as fashion design, element lamp multi-dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on. |
Technical Specification | ||||
Model | AMT3801AA | AMT3802AA | AMT3803AA | |
Optical System | Instrument Type | Single Beam Reflection Achromatic Optics System | ||
Mono Chromometer | Achromatic C-T ,Focus 350mm | |||
Dispersion elements | Grating system 1200line/mm characterization area 40??0mm2 Scintillation wavelength 250nm | |||
Bandwidth | 0.1,0.2,0.7,1.4mm Adjustable | |||
Wavelength Range | 190-900 | |||
Wavelength Accuracy | +-0.2 | |||
Wavelength Repeatability | 0.1nm max | |||
Resolution | Mn 3lines(279.5 & 279.8 Peak and Valley ??0% | |||
Spectrophotometric | Measurement | A,T,C | ||
Photometric Range | 0-125%, -0.1-3.00A | |||
Static Baseline Drift | (Cu) +-0.003A/30min | |||
Dynamic Baseline Drift | (Cu) +-0.006A/30min | |||
Background Correction | D-Lamp Background Correction >50times Correction Ability (1Abs) | |||
Atomization System | Flame | Graphite Furnace | Flame/Graphite Furnace | |
Flame | Characteristic Concentration | (Cu) 0.025ug/ml max | ---- | (Cu) 0.025ug/ml max |
Detection limit | (Cu) 0.004ug/ml max | ---- | (Cu) 0.004ug/ml max | |
Precision | RSD 0.6% max | ---- | RSD 0.6% max | |
Burner | titanium | ---- | titanium | |
Nebulizer | high-efficient Nebulizer | ---- | high-efficient Nebulizer | |
Spray chamber | anticorrosion material | ---- | anticorrosion material | |
Safety measures | Flame fuel gas, power assisted gas abnormal pressure protection | ---- | Flame fuel gas, power assisted gas abnormal pressure protection | |
Graphite Furnace | Characteristic quantity | ---- | Characteristic value Cd 0.5pg max Characteristic value Cu 20pg max | Characteristic value Cd 0.5pg max Characteristic value Cu 20pg max |
Detection Limit | ---- | Detection limit Cd 0.8 pg max | Detection limit Cd 0.8 pg max | |
Precision | ---- | Precision Cd , Cu 4% max | Precision Cd , Cu 4% max | |
Temperature Range | ---- | Room-temperature~3000°C | Room-temperature~3000℃ | |
High-Power Heating Range | ---- | 1500℃ ~ 3000℃ | 1500℃ ~ 3000℃ | |
Ramp time & Holding time | ---- | 1s ~ 255s | 1s ~ 255s | |
Heating Rate | ---- | Max Heating Rate 2000??S | Max Heating Rate 2000??S | |
Atomization Heating | ---- | Optical Control, Time Control,Normal | Optical Control, Time Control, Normal | |
Protect Gas Flow Rate out of Graphite Tube | ---- | 1 L/min | 1 L/min | |
Protect Gas Flow Rate in Graphite Tube | ---- | 0-50ml/min micro-flow, 300-400ml/min Fixed-Flow | 0-50ml/min micro-flow, 300-400ml/min Fixed-Flow | |
Safety measures | ---- | Cooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube Alarm | Cooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube Alarm | |
Data Process | Test Manner | Flame, Graphite Furnace, hydride-AA, flame emission | ||
Concentration | standard curve, standard addition, interpolation | |||
Times of repetitive | Measurement 1-30times, Average Value of A&C | |||
Report Print | parameters, data result | |||
Other | PC | exteriorization | ||
Dimension (mm) | 790 x 600 x 540 | 790 x 600 x 540 | 790 x 600 x 540 x 2 | |
Weight (kg) | 70 | 70 | 70+70 | |
Power Supply | (220±22)V, (50±1)Hz | |||
Temperature range | 10℃ ~ 30℃ | |||
Humidity range | 40% ~ 85% |
Note: AMT3803AA = AMT3801AA + AMT3802AA, technical specifications, profile and configuration may changed without notice
Micro Spectrophotometer AMS002 |
Features: AMS002 is the perfect instrument for almost lab dealing with sample analysis or preparation. It can accurately measure DNA, RNA and Oligonucleotide calculations, protein assays etc.. The system utilises CCD detector, a Xenon light source for long lamp lifetimes together with simply software. Simple pipette 0.5~2ul sample onto the pedestal, laying down the sampling arm, it can automatically complete the measurement within 5 seconds. 1. Direct, easy measurements in less than 5 seconds: just pipette & wipe 2. Full spectral output 3. Measures DNA, RNA (A260) and Protein (A280), concentrations and sample purity (260/280 ratio) 4. Large concentration range without dilutions 5. User-friendly software that includes Custom Methods and data export capabilities 6. Low-cost operation--no plates or other consumables |
Technical Specification: 1. Wavelength Range: 200~800nm 2. Minimum Sample Size: 0.5~2.0ul 3. Path Length: 0.2mm (For high concentration measwrement); 1.0mm (For ordinary) 4. Light Source: Xenon flash lamp 5. Detector Type: 3864-element linear silicon CCD array 6. Wavelength Accuracy: 1nm 7. Spectral Resolution: <3nm (FWHM at Hg 546 nm) 8. Absorbance Precision: 0.003Abs 9. Absorbance Accuracy: 1% (7.332Abs at 260 nm) 10. Absorbance Range: 0.02~90A (10mm equivalent) 11. Measurement Time: <5s 12. Dimensions (W x D x H): 200 x 250 x 166mm 13. Weight: 2.6kg 14. Sample Pedestal Material: Aluminum alloy and Quartz fiber 15. Operating Voltage: 24V DC 16. Operating Power Consumption: 20W 17. Standby Power Consumption: 5W 18. Software Compatibility: Windows 7, Windows XP |
Micro Spectrophotometer (Nucleic Acid Analyzer) AMS003 |
Features: AMS003 is a Nucleic Acid Analyzer designed for analyzing the concentration and pure of Nucleic Acid (DNA/RNA). Simply pipette 0.5~2ul sample onto the pedestal, laying down the sampling arm, it can automatically complete the measurement within 5 seconds. 1. Direct, easy measurements in less than 5 seconds 2. Require only 0.5~2ul samples 3. No cells or cuvettes and no warm up 4. Optional data output via built-in printer, SD-RAM Card, USB memory 5. Touch screen and panel operation, without computer 6. No dilutions for samples |
Technical Specification: 1. Wavelength Range: 230nm, 260nm, 280nm 2. Minimum Sample Size: 0.5~2.0ul 3. Path Length: 0.2mm (For high concentration measurement); 1.0mm (For ordinary) 4. Light Source: Xenon flash lamp 5. Absorbance Precision: 0.003Abs 6. Absorbance Range: 0.02~80A (10mm equivalent) 7. Detects Nucleic acid up to 10~4000ng/ul (dsDNA) 8. Detects Protein up to 0.1mg/ml~100mg/ml 9. Measurement Time: <5s 10. Dimensions (W x D x H): 210 x 268 x 181mm 11. Sample Pedestal Material: Aluminum alloy and Quartz fiber 12. Operating Voltage: 24V DC 13. Operating Power Consumption: 20W |
Biophotometer AMV20 |
AMV20 is a new designed model, suit for quick test of DNA, RNA and Protein. Features: 1.Can measure 0.5 ~ 2ul samples. 2.Quick measure without pre-warm. 3.There is no need to dilute the samples 4.Quick Scan, you can get the scanning curve in only 0.2 seconds. 5.Long life lamps, more than 2000 hours lifetime. 6.Software comes standard with the instruments. Specifications: Wavelength Range: 190nm ~ 850nm Wavelength Accuracy: 1nm Wavelength Resolution: 1nm Optical Accuracy: 0.002Abs Optical Range: 0.02 ~ 300Abs Measure Speed: 2 ~5 Seconds |
Color Spectrophotometer |
Features 1. Portable: Hand-held design, lightweight, can be run by batteries or AC adapter 2. Compact: Measurements can be taken from many different angles 3. 2.8" TFT display: Has multiple displays and features a display reversing function so screen can be read no matter which hand is holding the device. 4. Easy to use: Only has two main buttons. 5. SCI and SCE measurements: Can calculate and display both simultaneously 6. USB data output 7. Can print data with mini printer | |
Top popular model: AMT505B |
MODEL | AMT508 | AMT505A | AMT505B | AMT509A | AMT509B | AMT510A | AMT510B |
Measuring Caliber | 8mm | 8mm | 4mm | 8mm | 4mm | 8mm | 4mm |
Repeatability | Light splitting reflectivity: standard deviation within 0.08% | ||||||
Color Values: ΔE*ab<=0.03 | Color Values: ΔE*ab<=0.03 | Color Values: ΔE*ab<=0.02 | Color Values: ΔE*ab<=0.15 | ||||
Data Storage | 20000 | 40000 | |||||
Sensor | blue light enhanced sensor array | dual light path sensor array | |||||
Light Source Longevity | 5 years, 1.5 million tests | 10 years, 3 million tests | |||||
Interface | USB | USB, Bluetooth | |||||
Measurement Time Interval | 2s | 0.5s | |||||
Color Space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectivity | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectivity, Hunterlab, Munsell MI, CMYK | |||||
Color Difference Formulas | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, ΔE*00 | ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, ΔE*00, ΔEab (Hunter), 555, color classification | |||||
Other Colorimetric Indices | WI (ASTM E313-10, ASTM E313- 73, CIE/ISO, AATCC, Hunter, Taube, Berger, Ganz, Stensby, Metamerism index Milm, adhesive/changing color fastness | WI (ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube, Berger, Stensby), YI (ASTM D1925, ASTM E313-00, ASTM E313-73), Tint (ASTM E313, CIE, Ganz), Metamerism index Milm, adhesive/changing color fastness, ISO luminance,8 gloss, A density, T density, E density, M density. | |||||
Color Matching System | Not Match | Match | |||||
Battery Capacity | Rechargeable, 10000 Continuous Tests | Rechargeable, 20000 Continuous Tests |
Other Specifications which are all same | |
Illumination | d/8 (Diffused lighting, 8 degrees observe angle); SCS optical engine (light splitting and integration system), ETC (real time calibration technology), SCI (specular reflection included)/SCE (specular reflection excluded) simultaneous measurement. (conform to CIE No.15, ISO 7724/1, ASTM E1164, DIN 5033 Teil7, JIS Z8722 Condition c standards) |
Sphere Size | Φ40mm, Alvan diffused reflection surface coating |
Wavelength Range | 400nm-700nm |
Wavelength Interval | 10nm |
Half Spectral Width | 5nm |
Reflectance Range | 0 ~ 200% |
Reflectance Resolution | 0.01% |
Observation Angle | 2° / 10° |
Measurement Light Source | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
Data Being Displayed | SPD distribution/data, sample's color values, color difference values/graph, pass/fail results, color error tendency, color simulation, display measurement area ect. |
Measurement Time | 1s |
Inter Instrument Agreement | ΔE*ab within 0.2 (BCRA color charts II, average of the 12 charts) |
Size | 181x73x112mm (L*W*H) |
Weight | 550g |
Display Screen | True color screen that includes all colors |
Operating Temp./RH | 0 ~45°C, RH 80% or less (at 35°) with no condensation |
Storage Temp./RH | -25 ~55°C, RH 80% or less (at 35°) with no condensation |
Display screen | 2.8 inch TFT |
UV Light Source | Not Include |
Standard Accessories | DC adapter, Lithium battery, manual, color management software, drive software, electronic manual, color management guide, USB cable, black/white calibration tube |
Optional Accessories | MINI Printer, Powder Molding Device |
Color Spectrophotometer AMT505H |
Features 1. Portable: Hand-held design, lightweight, can be run by batteries or AC adapter 2. Compact: Measurements can be taken from many different angles 3. 2.8" TFT display: Has multiple displays and features a display reversing function so screen can be read no matter which hand is holding the device. 4. Easy to use: Only has two main buttons. 5. SCI and SCE measurements: Can calculate and display both simultaneously 6. USB data output 7. Can print data with mini printer |
Illumination/Observation system | D/8 (diffuse illumination, 8° reception, SCE/SCI) |
Sensor | Photoelectric diode array |
Integrating Sphere Diameter | 40mm |
Wavelength range | 400nm ~ 700nm |
Wavelength interval | 10nm |
Half bandwidth | <=14nm |
Reflectance range | 0 to 175%, resolution: 0.1% |
Light source | Composite LED |
Measurement time | Approx 1.5 seconds |
Measuring caliber | 8mm |
Repeatability | The standard deviation within 0.2%; Colorimetric Value: Standard deviation within ΔE*ab 0.08 |
Inter instrument agreement | Within ΔE*ab 0.4/ Standard color boards |
Languages | Chinese, English |
Standard observer | 2°, 10° (CIE 1931/2°, CIE 1964/10°) |
Observation light source | A,C,D50,D65,F2,F6,F7,F8, F10, F11, F12 (can select two light sources for display at same time) |
Displayed data | Spectral value/chart, colorimetric value, chromatic aberration value, pass/fail, color simulation. |
Color space/standards | L*a*b*, L*C*h, ΔE*ab (CIE1976), ΔE*ch, ΔE*94 (CIE1994), ΔE00 (CIE2000), CMC(1:1), CMC(2:1), Yxy, XYZ, WI (ASTM E313/CIE), YI (ASTM E313/ASTMD1925), ISO Brightness (ISO2470), Density status A/T, CIE00, WI/Tint |
Data storage | 100*200 (100 of standard samples, with maximum of 200 records under each standard sample) |
Interface port | USB |
Power source | lithium battery, DC adapter |
Operating temp./ humidity | 5 ~40°, RH 80% or less (at 35°) with no condensation |
Storage temp. / humidity | 0 ~45°, RH 80% or less (at 35°) with no condensation |
Display screen | 2.8 inch TFT |
UV Fluorescence | Without UV |
Color Spectrophotometer |
Model | AMT528 | AMT529 | AMT530 |
Illumination/observation system | 45°/0° | D/8° | |
Integrating Sphere Size | Φ58mm | ||
Light Source | Combined LED Sources | ||
Sensor | Silicon Photodiode Array | ||
Wavelength Range | 400~700nm | ||
Wavelength Pitch | 10nm | ||
Reflectance Range | 0~200% | ||
Measuring Aperture | Φ8mm | Φ4mm | |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV | CIE LAB, XYZ, Yxy, LCh, CIE LUV, LAB & WI & YI | |
Color difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00 | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*cmc(l:c), CIE2000ΔE*00, ΔE(h) | |
Other Chromaticity Data | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), Metamerism Index (Mt), Color Stain, Color Fastness | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), Metamerism Index (Mt), Strength Color Stain, Color Fastness | |
Observer | 2°/10° | ||
Illuminant | D65, A, C, D50, D55, D75, F2, F6, F7, F8, F10, F11, F12 | D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10 (TPL5), F11(TL84), F12 (TL83/U30) | |
Display Data | Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation | Spectral Value/Graph, Colorimetric Value, Color Difference Value/Graph, PASS/FAIL Result, Color Offset, Color Simulation, color index setting (ΔE*94, ΔE*cmc, ΔE2000), tolerance prompt, reverse prompt, time setting, language setting, restore factory setting | |
Measurement Time | 1.5s | 1.2s | |
Repeatability Spectral Reflectance | standard deviation within 0.1%, (400~700nm: within 0.2%) | Spectral Reflectance: standard deviation within 0.1%, (400~700nm: within 0.2%), Colorimetric Value: Standard deviation within ΔE*ab 0.04 | |
Colorimetric Value | Standard deviation within ΔE*ab 0.04 | ||
Inter Instrument Agreement | Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles) | ||
Dimension | L*W*H=90*77*230mm | ||
Weight | 600g | ||
Battery | Li-ion battery 5000 times within 8 hours | Li-ion battery. 2800 times within 8 hours | |
Lamp Life | 5 years, more than 1.6 million measurements | ||
Display Screen | TFT 3.5inch, Capacitive Touch Screen | ||
Interface | USB/RS-232 | ||
Data Memory | 1000 Standards, 15000 Samples | ||
Optional Accessory | Micro Printer, Universal Test Box |
Visible Spectrophotometer AMV01 |
Features ●Large LCD screen (128x64 Dots). ●Can display and save 50 groups of data, 3 groups per screen. ●Data can be restored after a sudden power cut. ●Auto setting wavelength. ●Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. ●Automatic WL. calibration and dark current getting. ●Optional software UV-Professional can expand the applications to Kinetics and Quantitative. |
Optical System | Single beam, Grating 1200 lines/mm |
Wavelength Range | 325-1000nm |
Bandwidth | 4nm |
Wavelength Accuracy | +-1nm |
Wavelength Repeatability | 0.5nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.5%T |
Photometric Repeatability | 0.3%T |
Photometric Range | -0.3-3A,0-200%T |
Stray Light | 0.3%T max |
Stability | +-0.002A/h @ 500nm |
Display | 128*64 Dots LCD |
Detector | Silicon Photodiode |
Standard Cell Holder | 4-position 10mm cell changer |
Light Source | Tungsten Lamp |
Output | USB Port & Parallel Port (Printer) |
Power Requirements | AC 85~250V |
Dimension | 420*280*180mm |
Weight | 10kg |
Visible Spectrophotometer AMV02, AMV02PC (with scan software) |
Low Stray Light: The stray light is below 0.05%T.The monochromator is totally sealed and the optical surfaces are protected with a silicon dioxide membrane. The excellent optical system and electric circuit design ensures the very low stray light. Large LCD display: adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. Large Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. Can upgrade to scanning model: The instrument can be controlled by our scanning software UV-Professional developed based on Windows® through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
Wavelength Range | 320-1100nm |
Bandwidth | 2nm |
Wavelength Accuracy | +-0.8nm |
Wavelength Repeatability | 0.3nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -0.3-3A, 0-200%T,0-9999C |
Stability | +-0.002A/h @ 500nm |
Baseline Flatness | +-0.002A/h |
Stray Light | 0.05%T max |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*360*225mm |
Weight | 18kg |
Visible Spectrophotometer AMV03, AMV03PC (with scan software) |
Low Stray Light: The stray light is below 0.05%T.The monochromator is totally sealed and the optical surfaces are protected with a silicon dioxide membrane. The excellent optical system and electric circuit design ensures the very low stray light. Large LCD display: adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. Large Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. Can upgrade to scanning model: The instrument can be controlled by our scanning software UV-Professional developed based on Windows® through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
Wavelength Range | 320-1100nm |
Bandwidth | 2nm |
Wavelength Accuracy | +-0.5nm |
Wavelength Repeatability | 0.2nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -0.3-3A,0-200%T,0-9999C |
Stability | +-0.002A/h @500nm |
Baseline Flatness | +-0.0015A/h |
Stray Light | 0.05%T max |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*360*225mm |
Weight | 18kg |
UV Spectrophotometer Large LCD Scanning AMV05, AMV05PC (with scan software) |
1. The innovative optical layout and state of art mono-chromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long term stability and durability. 2. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/vis spectrum starting from 190nm and into the near-infrared 1100nm. 3. Online software upgrade capability via Internet (for stand-alone models) 4. Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. 5. Real-time clock for date and time stamping of results 6. Large LCD display (320*240 Dots Matrix) |
Wavelength Range | 190-1100nm |
Bandwidth | 1.8nm |
Wavelength Accuracy | +-0.5nm |
Wavelength Repeatability | 0.3nm |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -0.3-3A,0-200%T,0-9999C |
Stability | +- 0.002A/h @ 500nm |
Baseline Flatness | +- 0.002A/h |
Noise | +- 0.001A/h |
Stray Light | 0.05%T max @ 220nm,360nm |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 320*240 Dots LCD |
Lamps | D2 Lamp & W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*380*180mm |
Weight | 20kg |
UV Spectrophotometer Large LCD Scanning AMV06, AMV07, AMV08 |
1. The innovative optical layout and state of art mono-chromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long term stability and durability. 2. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 1100nm. 3. Online software upgrade capability via Internet (for stand-alone models) 4. Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. 5. Real-time clock for date and time stamping of results 6. Large LCD display (320*240 Dots Matrix) |
Model | AMV06 | AMV07 | AMV08 |
Wavelength Range | 190-1100nm | ||
Bandwidth | 1.8nm | 1nm | 0.5/1.0/2.0/4.0nm |
Wavelength Accuracy | +-0.3nm | ||
Wavelength Repeatability | 0.2nm | ||
Photometric Accuracy | +-0.3%T | ||
Photometric Repeatability | 0.2%T | ||
Photometric Range | -0.3-3A,0-200%T,0-9999C | ||
Stability | +-0.002A/h @ 500nm | ||
Baseline Flatness | +-0.001A/h | ||
Noise | +-0.001A/h | ||
Stray Light | 0.05%T max @ 220nm,360nm | ||
Data Output Port | USB | ||
Printer Port | Parallel Port | ||
Display | 320*240 Dots LCD | ||
Lamps | D2 Lamp & W Lamp | ||
Detector | Silicon Photodiode | ||
Power Requirements | AC 220V/50Hz or 110V/60Hz | ||
Dimension | 625*430*206mm | ||
Weight | 28kg |
UV Spectrophotometer AMV09 |
1. Large LCD screen (128x64 Dots). 2. Can display and save 50 groups of data, 3 groups per screen. 3. Data can be restored after a sudden power cut. 4. Auto setting wavelength. 5. Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. 6. Automatic WL. calibration and dark current getting. 7. Optional software UV-Professional can expand the applications to Kinetics and Quantitatives. |
Optical System | Single beam, Grating 1200 lines/mm |
Wavelength Range | 200-1000nm |
Bandwidth | 4nm |
Wavelength Accuracy | +-1nm |
Wavelength Repeatability | 0.5nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.5%T |
Photometric Repeatability | 0.3%T |
Photometric Range | -0.3-3A,0-200%T |
Stray Light | 0.3%T max |
Stability | +-0.002A/h @ 500nm |
Display | 128*64 Dots LCD |
Detector | Silicon Photodiode |
Standard Cell Holder | 4-position 10mm cell changer |
Light Source | Tungsten & Deuterium lamp |
Output | USB Port & Parallel Port (Printer) |
Power Requirements | AC 85~250V |
Dimension | 420*280*180mm |
Weight | 12kg |
UV Spectrophotometer AMV10, AMV10PC (with scan software) |
1. Large LCD screen(128x64Dots). Can display total 200 groups of data,5 groups per screen. Can display standard curve and the curve equation. 2. Can save 200 groups of curve equation. Convenient for check and reload. 3. Data can be restored after a sudden power cut. 4. Auto setting wavelength. Auto zero and blank. 5. Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. 6. The application software UV-Professional provides complete control of the spectrophotometer from a computer through the Built-in USB port. The following functions can be easily achieved: Quantitative, Kinetics, Wavelength Scan, DNA/Protein Test and Multi-wavelength Test. 7. The flange of the D2 lamp makes it become true Pre-aligned design makes it convenient to change lamps. 8. Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice. |
Optical System | Single beam, Grating 1200 lines/mm |
Wavelength Range | 190-1100nm |
Bandwidth | 2nm |
Wavelength Accuracy | +-1nm |
Wavelength Repeatability | 0.5nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -0.3-3A,0-200%T,0-9999C |
Stability | +-0.002A/h @ 500nm |
Stray Light | 0.1%T max |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | D2 Lamp & W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*360*225mm |
Weight | 18kg |
UV Spectrophotometer AMV11, AMV11PC (with scan software) |
1. Large LCD screen(128x64Dots).Can display total 200 groups of data,5 groups per screen. Can display standard curve and the curve equation. 2. Can save 200 groups of curve equation. Convenient for check and reload. 3. Data can be restored after a sudden power cut. 4. Auto setting wavelength. Auto zero and blank. 5. Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. 6. The application software UV-Professional provides complete control of the spectrophotometer from a computer through the Built-in USB port. The following functions can be easily achieved: Quantitative, Kinetics, Wavelength Scan, DNA/Protein Test and Multi-wavelength Test. 7. The flange of the D2 lamp makes it become true Pre-aligned design makes it convenient to change lamps. 8. Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice. |
Optical System | Single beam, Grating 1200 lines/mm |
Wavelength Range | 190 ~ 1100nm |
Bandwidth | 2nm |
Wavelength Accuracy | +-0.5nm |
Wavelength Repeatability | 0.3nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.5%T |
Photometric Repeatability | 0.3%T |
Photometric Range | -0.3-3A,0-200%T,0-9999C |
Stability | +-0.002A/h @ 500nm |
Stray Light | 0.1%T max |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | D2 Lamp & W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*360*225mm |
Weight | 18kg |
UV Spectrophotometer AMV12, AMV12PC (with scan software) |
Low Stray Light: The stray light is below 0.05%T.The monochomator is totally sealed and the optical surfaces are protected with a silicon dioxide membrane. The excellent optical system and electric circuit design ensures the very low stray light. Large LCD display: it adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. Large Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. Can upgrade to scanning model: The instrument can be controlled by the scanning software UV-Professional developed based on Windows through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
Wavelength Range | 190-1100nm |
Bandwidth | 2nm |
Wavelength Accuracy | 0.5nm |
Wavelength Repeatability | 0.2nm |
Wavelength Setting | Auto |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -0.3-3A,0-200%T,0-9999C |
Stability | +-0.002A/h @ 500nm |
Baseline Flatness | +-0.0015A/h |
Stray Light | 0.05%T max |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 128*64 Dots LCD |
Lamps | D2 Lamp & W Lamp |
Detector | Silicon Photodiode |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 460*360*225mm |
Weight | 18kg |
UV Spectrophotometer AMV23, AMV23PC (with scan software) |
Low Stray Light: The stray light of AMV23(PC) is below 0.05%T.The monochomator is totally sealed and the optical surfaces are protected with a silicon dioxide membrane. The excellent optical system and electric circuit design ensures the very low stray light. Large LCD display: Models AMV23(PC) adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also,it can display 5 groups of data per screen. Large Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. Can upgrade to scanning model: The instrument can be controlled by our scanning software UV-Professional developed based on Windows through the USB port. The software expands the function to Quantitative, Kinetics, Multi-wavelength and Wavelength Scanning. | |
Specifications: 1. Wavelength Range: 190~1100nm 2. Bandwidth: 2nm 3. Wavelength Accuracy: ±0.8nm 4. Wavelength Repeatability: 0.3nm 5. Wavelength Setting: Auto 6. Photometric Accuracy: ±0.3%T 7. Photometric Repeatability: 0.2%T 8. Photometric Range: -0.3-3A,0-200%T,0-9999C 9. Stability: ±0.002A/h @ 500nm 10. Baseline Flatness: ±0.002A/h 11. Stray Light: <0.05%T 12. Data Output Port: USB 13. Printer Port: Parallel Port 14. Display: 128*64 Dots LCD 15. Lamps: D2 Lamp & W Lamp 16. Detector: Silicon Photodiode 17. Power Requirements: AC220V/50Hz or 110V/60Hz 18. Dimension: 460*360*225mm 19. Weight: 18kg |
Double Beam UV Spectrophotometer AMV15 |
1. The innovative optical layout and state of art mono-chromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long term stability and durability. 2. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 900nm. 3. Online software upgrade capability via Internet (for stand-alone models) 4. Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. 5. Real-time clock for date and time stamping of results 6. Large LCD display (320*240 Dots Matrix) |
Wavelength Range | 190-1100nm |
Bandwidth | 0.1/0.2/0.5/1.0/2.0/4.0nm |
Wavelength Accuracy | +-0.3nm |
Wavelength Repeatability | 0.2nm |
Photometric Accuracy | +-0.3%T |
Photometric Repeatability | 0.2%T |
Photometric Range | -4-4A,0-200%T,0-9999C |
Stability | +-0.0004A/h @ 500nm |
Baseline Flatness | +-0.001A/h |
Noise | +-0.0004A/h |
Stray Light | 0.01%T max @ 220nm,360nm |
Data Output Port | USB |
Printer Port | Parallel Port |
Display | 320*240 Dots LCD |
Lamps | D2 Lamp & W Lamp |
Power Requirements | AC 220V/50Hz or 110V/60Hz |
Dimension | 635*440*210mm |
Weight | 30kg |
Double Beam UV Spectrophotometer AMV16, AMV17, AMV18 |
1. The innovative optical layout and state of art mono-chromator with high grade blazed holographic grating ensure accuracy. Its integrated design assures long term stability and durability. 2. The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 900nm. 3. Online software upgrade capability via Internet (for stand-alone models) 4. Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. 5. Real-time clock for date and time stamping of results 6. Large LCD display (320*240 Dots Matrix) |
Model | AMV16 | AMV17 | AMV18 |
Optical System | Double Beam(1200 Lines/mm Grating) | ||
Wavelength Range | 190-1100nm | ||
Bandwidth | 1.8nm | 1nm | 0.5/1.0/2.0/4.0nm |
Wavelength Accuracy | +-0.3nm | ||
Wavelength Repeatability | 0.2nm | ||
Photometric Accuracy | +-0.3%T | ||
Photometric Repeatability | 0.2%T | ||
Photometric Range | -0.3-3A,0-200%T,0-9999C | ||
Stability | +-0.001A/h @ 500nm | ||
Baseline Flatness | +-0.001A/h | ||
Noise | +-0.001A/h | ||
Stray Light | 0.05%T max @ 220nm,360nm | ||
Data Output Port | USB | ||
Printer Port | Parallel Port | ||
Display | 320*240 Dots LCD | ||
Lamps | D2 Lamp & W Lamp | ||
Detector | Silicon Photodiode | ||
Power Requirements | AC 220V/50Hz or 110V/60Hz | ||
Dimension | 625*430*206mm | ||
Weight | 30kg |