| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows setting the 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
|
| Specifications: |
Model | ION320 |
pH | |
| Range | -2.000~20.000pH |
| Accuracy | ±0.002pH |
| Resolution | 0.1, 0.01, 0.001pH, Selectable |
| Calibration Points | 1 to 5 points |
| Calibration Solutions | USA, NIST, DIN or User-defined |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1, 1mV, Selectable |
| Calibration Points | 1 point (Only for Relative mV mode) |
| Calibration Range | ±200mV |
| lon | |
| Range | 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
| Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Points | 1 point |
| Calibration Solutions | Measured value ±10°C |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
|
| Specifications: |
Model | ION321-F |
| lon | |
| Range | 1×10-6M~Saturation, 0.02ppm~Saturation |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
|
| Specifications: |
Model | ION321-CL |
| lon | |
| Range | 5×10-6~1M, 1.8~35500ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
|
| Specifications: |
Model | ION321-Na |
| lon | |
| Range | 1×10-5~1M, 0.1~23000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
|
| Specifications: |
Model | ION321-Ca |
| lon | |
| Range | 5×10-7~1M, 0.02~4000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-NO3 |
| lon | |
| Range | 7×10-6~1M, 0.4~62000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Br |
| lon | |
| Range | 5×10-6~1M, 0.4~79900ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-NH4 |
| lon | |
| Range | 5×10-6~1M, 0.1~18000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Cn |
| lon | |
| Range | 5×10-6~0.01M, 0.2~260ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Cd |
| lon | |
| Range | 1×10-6~0.1M, 0.01~11200ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Cu |
| lon | |
| Range | 1×10-8~0.1M, 0.006~6400ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-I |
| lon | |
| Range | 5×10-8~0.1M, 0.006~127000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Pb |
| lon | |
| Range | 1×10-8~0.1M, 0.2~20700ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-Ag |
| lon | |
| Range | 1×10-7~1M, 0.01~107900ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-K |
| lon | |
| Range | 1×10-6~1M, 0.04~39000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-S |
| lon | |
| Range | 1×10-7~1M, 0.003~32100ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
|
| Specifications: |
Model | ION321-NH3 |
| lon | |
| Range | 1×10-6~1M, 0.02~17000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Power Requirements | 3×1.5V "AA" Batteries |
| Battery Life | Approximately 150 hours (Turn off the backlit) |
| Dimensions | 170(L)×85(W)×30(H)mm |
| Weight | 300g |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION930 |
pH | |
| Range | -2.000~20.000pH |
| Accuracy | ±0.002pH |
| Resolution | 0.1, 0.01, 0.001pH, Selectable |
| Calibration Points | 1 to 5 points |
| Calibration Solutions | USA, NIST, DIN or User-defined |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1, 1mV, Selectable |
| Calibration Points | 1 point (Only for Relative mV mode) |
| Calibration Range | ±200mV |
| lon | |
| Range | 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
| Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Points | 1 point |
| Calibration Range | Measured value ±10°C |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Na |
| lon | |
| Range | 1×10-5~1M, 0.1~23000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-F |
| lon | |
| Range | 1×10-6M~Saturation, 0.02ppm~Saturation |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-CL |
| lon | |
| Range | 5×10-6~1M, 1.8~35500ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Ca |
| lon | |
| Range | 5×10-7~1M, 0.02~4000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-NO3 |
| lon | |
| Range | 7×10-6~1M, 0.4~62000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Br |
| lon | |
| Range | 5×10-6~1M, 0.4~79900ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-NH4 |
| lon | |
| Range | 5×10-6~1M, 0.1~18000ppm |
| Accuracy | ±0.5% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Cn |
| lon | |
| Range | 5×10-6~0.01M, 0.2~260ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Cd |
| lon | |
| Range | 1×10-6~0.1M, 0.01~11200ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Cu |
| lon | |
| Range | 1×10-8~0.1M, 0.006~6400ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-I |
| lon | |
| Range | 5×10-8~1M, 0.06~127000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Pb |
| lon | |
| Range | 1×10-8~0.1M, 0.2~20700ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-Ag |
| lon | |
| Range | 1×10-7~1M, 0.01~107900ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-K |
| lon | |
| Range | 1×10-6~1M, 0.04~39000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-S |
| lon | |
| Range | 1×10-7~1M, 0.003~32100ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |
| Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
|
| Specifications: |
Model | ION931-NH3 |
| lon | |
| Range | 1×10-6~1M, 0.02~17000ppm |
| Accuracy | ±1% F.S |
| Resolution | 0.001, 0.01, 0.1, 1 |
| Calibration Points | 2 to 5 points |
| Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
| mV | |
| Range | -1999.9~1999.9mV |
| Accuracy | ±0.2mV |
| Resolution | 0.1mV |
| Temperature | |
| Range | 0~105°C, 32~221°F |
| Accuracy | ±0.5°C, ±0.9°F |
| Resolution | 0.1°C |
| Calibration Range | Measured value ±10°C |
| Temperature Units | °C or °F |
| Others | |
| Temperature Compensation | 0~100°C, 32~212°F |
| Compensation Mode | Manual or Automatic |
| Hold Function | Manual or Automatic |
| Stability Conditions | Low or High |
| Calibration Due | 0 to 31 days |
| Power Off | Manual or Automatic (10, 20, 30 minutes) |
| Reset Function | Yes |
| Memory | Stores up to 500 data sets |
| Output | USB Communication Interface |
| Connector | BNC |
| Display | LCD (130×110mm) |
| Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
| Dimensions | 210(L)×188(W)×60(H)mm |
| Weight | 1.5kg |