Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows setting the 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
Model | ION320 |
pH | |
Range | -2.000~20.000pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH, Selectable |
Calibration Points | 1 to 5 points |
Calibration Solutions | USA, NIST, DIN or User-defined |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1, 1mV, Selectable |
Calibration Points | 1 point (Only for Relative mV mode) |
Calibration Range | ±200mV |
lon | |
Range | 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Points | 1 point |
Calibration Solutions | Measured value ±10°C |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
Model | ION321-F |
lon | |
Range | 1×10-6M~Saturation, 0.02ppm~Saturation |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
Model | ION321-CL |
lon | |
Range | 5×10-6~1M, 1.8~35500ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
Model | ION321-Na |
lon | |
Range | 1×10-5~1M, 0.1~23000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use the meter smoothly. |
Specifications: |
Model | ION321-Ca |
lon | |
Range | 5×10-7~1M, 0.02~4000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-NO3 |
lon | |
Range | 7×10-6~1M, 0.4~62000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Br |
lon | |
Range | 5×10-6~1M, 0.4~79900ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-NH4 |
lon | |
Range | 5×10-6~1M, 0.1~18000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Cn |
lon | |
Range | 5×10-6~0.01M, 0.2~260ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Cd |
lon | |
Range | 1×10-6~0.1M, 0.01~11200ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Cu |
lon | |
Range | 1×10-8~0.1M, 0.006~6400ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-I |
lon | |
Range | 5×10-8~0.1M, 0.006~127000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Pb |
lon | |
Range | 1×10-8~0.1M, 0.2~20700ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-Ag |
lon | |
Range | 1×10-7~1M, 0.01~107900ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-K |
lon | |
Range | 1×10-6~1M, 0.04~39000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-S |
lon | |
Range | 1×10-7~1M, 0.003~32100ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • High performance portable fluoride ion meter is equipped with a large LCD display. • 2 to 5 points calibration from low to high concentrations. • Direct ion concentration readout simplifies the elaborate measurement process. • Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L. • Automatic Temperature Compensation provides accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable reading for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • mV measurement mode allows user to check performance of the ion selective electrode. • Automatic electrode diagnosis shows the slope of sensor. • Help message as a operational guide that helps you quickly begin using the meter. • System menu can be used to set 8 parameters, including the number of calibration points, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface. • Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that usethe meter smoothly. |
Specifications: |
Model | ION321-NH3 |
lon | |
Range | 1×10-6~1M, 0.02~17000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 3×1.5V "AA" Batteries |
Battery Life | Approximately 150 hours (Turn off the backlit) |
Dimensions | 170(L)×85(W)×30(H)mm |
Weight | 300g |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION930 |
pH | |
Range | -2.000~20.000pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH, Selectable |
Calibration Points | 1 to 5 points |
Calibration Solutions | USA, NIST, DIN or User-defined |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1, 1mV, Selectable |
Calibration Points | 1 point (Only for Relative mV mode) |
Calibration Range | ±200mV |
lon | |
Range | 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE) |
Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Points | 1 point |
Calibration Range | Measured value ±10°C |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Na |
lon | |
Range | 1×10-5~1M, 0.1~23000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-F |
lon | |
Range | 1×10-6M~Saturation, 0.02ppm~Saturation |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-CL |
lon | |
Range | 5×10-6~1M, 1.8~35500ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Ca |
lon | |
Range | 5×10-7~1M, 0.02~4000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-NO3 |
lon | |
Range | 7×10-6~1M, 0.4~62000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Br |
lon | |
Range | 5×10-6~1M, 0.4~79900ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-NH4 |
lon | |
Range | 5×10-6~1M, 0.1~18000ppm |
Accuracy | ±0.5% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Cn |
lon | |
Range | 5×10-6~0.01M, 0.2~260ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Cd |
lon | |
Range | 1×10-6~0.1M, 0.01~11200ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Cu |
lon | |
Range | 1×10-8~0.1M, 0.006~6400ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-I |
lon | |
Range | 5×10-8~1M, 0.06~127000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Pb |
lon | |
Range | 1×10-8~0.1M, 0.2~20700ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-Ag |
lon | |
Range | 1×10-7~1M, 0.01~107900ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-K |
lon | |
Range | 1×10-6~1M, 0.04~39000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-S |
lon | |
Range | 1×10-7~1M, 0.003~32100ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |
Features: • Automatic Temperature Compensation ensures accurate reading over the entire range. • Calibration Due Reminder prompts user to calibrate the meter regularly. • Stability indicator automatically shows current measurement status. • Auto-Hold function freezes stable measured value for easy viewing and recording. • Manual temperature calibration improves the measurement accuracy of meter. • Selectable temperature unit (°C or °F) meets different application requirements. • Automatic electrode diagnosis shows zero point offset and slope of the electrode. • Help message as a operational guide that helps you quickly begin using the meter. • System menu allows the setting 10 parameters, including the pH buffer standard, number of calibration points, resolution, stability condition, hold function, etc. • Reset feature automatically resumes all parameters back to factory default settings. • Expanded memory stores and recalls up to 500 readings. • Built-in real-time clock stamps stored data to meet GLP standard. • Stored data can be transferred into computer by USB communication interface.. |
Specifications: |
Model | ION931-NH3 |
lon | |
Range | 1×10-6~1M, 0.02~17000ppm |
Accuracy | ±1% F.S |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration Points | 2 to 5 points |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L |
mV | |
Range | -1999.9~1999.9mV |
Accuracy | ±0.2mV |
Resolution | 0.1mV |
Temperature | |
Range | 0~105°C, 32~221°F |
Accuracy | ±0.5°C, ±0.9°F |
Resolution | 0.1°C |
Calibration Range | Measured value ±10°C |
Temperature Units | °C or °F |
Others | |
Temperature Compensation | 0~100°C, 32~212°F |
Compensation Mode | Manual or Automatic |
Hold Function | Manual or Automatic |
Stability Conditions | Low or High |
Calibration Due | 0 to 31 days |
Power Off | Manual or Automatic (10, 20, 30 minutes) |
Reset Function | Yes |
Memory | Stores up to 500 data sets |
Output | USB Communication Interface |
Connector | BNC |
Display | LCD (130×110mm) |
Power Requirements | DC5V, using AC adapter, 220VAC/50Hz |
Dimensions | 210(L)×188(W)×60(H)mm |
Weight | 1.5kg |