DoseRAE 2 is a compact, direct-reading and alarming electronic personal radiation detector. It uses a diode and a scintillation crystal to detect X- and gamma radiation, and provides real-time monitoring of personal dose and dose rate. The real-time radiation dose rate monitoring allows immediate reaction in case of radiation occurrences and thus reduces the radiation exposure. By measuring dose equivalent and dose equivalent rate, this detector provides the functions of a dosimeter too. It also measures radiation exposure and exposure rate, which is appropriate for controlling the exposure of emergency responders to photon radiation. | |
Applications • Nuclear power plants • Environmental survey • Fire Departments • Hazardous Material Response Teams • Police • EMS • Military • Hospitals | |
Key Features • Stand-alone electronic dosimeter with LCD display • Multiple units with reader and software can be used as a dosimetry system • Continuous digital dose rate readout • Continuously accumulated total dose readout • Prominent visible, audible, and vibration alarms • Long calibration life • Two operation keys, simple intuitive programming | |
Specifications 1. Gamma Sensors: CsI (TI) + photodiode (low environment radiation); Energy-compensated PIN diode (level of radiation protection) 2. Dose Rate Range: 0.01μSv/h to 10Sv/h 3. Accuracy of Dose Rate: ±20% (from 10μSv/h to 10 Sv/h); ±30% (from 0.01μSv/h to 10μSv/h) 4. Dose Range: 0μSv to 10Sv 5. Dose Accuracy: ±15% 6. Energy Range 20 keV to 6 MeV for X- and gamma radiations 7. Size 3.3" x 2.2" x 0.4" (85 x 55 x 9.6 mm) without clip 8. Weight 1.8 oz. (50g) with battery and clip 9. Battery LIR2450 Rechargeable batteries, 10. Operating Hours Up to 200 hours after each charge (one week continuous use) 11. Datalog Size More than 3000 data points 12. Datalog Interval User programmable, from 30 to 3,600 seconds 13. Communication USB interfaces with computer for datalog download 14. Alarms: Loud audible buzzer (85+dB @ 30 cm/12"), Highly visible LED lights, Built-in vibration alarm 15. Alarm Settings: Dose alarm (adjustable from 1.0 μSv to 10 Sv); Dose rate alarm (adjustable from 1.0 μSv/h to 10 Sv/h) 16. Temperature -20ºC to 50ºC (-4ºF to 122ºF) 17. Humidity 0% to 95% (non-condensing) 18. IP Rating IP-54 19. Shock Resistance Passes drop test from 1.5 m (59") |
Features: 1. An electromagnetic wave simply means the wave motion of the electromagnetic field (EMF). 2. This meter is applied to measuring electromagnetic fields of extremely low frequency (ELF) of 30Hz to 300Hz. 3. It is capable of measuring the electromagnetic field radiation intensity that is produced from electric transmission equipment, power line, electric oven, air conditioner, refrigerator, computer monitor, video/audio device and so forth. 4. The magnetic field unit is Tesla (T), Gauss (G), micro-Tesla (uT) or milli-Gauss (mG). 5. Data hold, Maximum hold, Overload indication, Low battery indication. Specifications: Range: 200 ~ 2000mG; 20 ~ 200μT Accuracy: ±2.5% at 50Hz/60Hz Resolution: 0.1/1mG, 0.01/0.1μT Frequency response: 30 ~ 300Hz Sensor: Single Axis Power DC: 9V battery Dimension: 130 x 56 x 38 mm Weight: 180g |
Functional and technical parameters Unit: field : V / m, the magnetic field μT Accuracy : electric: 1V / m, magnetic 0.01μT Range : electric: 1-1999V / m, magnetic 0.01-19.99μT Alarm Threshold : electric: 40V / m, magnetic 0.4μT Test Bandwidth : 3-1 / 2 LCD display Sampling time : 5Hz-3500MHz Test mode : approx. 0.4 seconds Overload Tip : measured with dual-mode Data lock : LCD displays "1" Low Light Display : √ Automatic shutdown : √ Average and peak : √ Low power tips : √ Operating Temperature : 0oC-50oC Operating Humidity : 80% Operating voltage : 9V Dimensions : 63.6 * 31 * 125.8mm Weight : 146g Power : 6F229V battery |
FEATURES: The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths. Display micro Tesla & milli Gauss in the same tester. Data hold, Peak hold function On-line computer (1391/1392) Data logging (1392) function. | |
SPECIFICATION: |
Display | 3-1/2 digits. Max. indication 1999 |
Range | 200/2000 milli Gauss; 200micro Tesla |
Resolution | 0.1/1 milli Gauss; 0.01/0.1 micro Tesla |
Number of Axis | Single axis |
Band Width | 30 Hz to 300 Hz |
Accuracy | +/- (3% + 3d) at 50Hz / 60Hz |
Over-Input | Display shows "OL" |
Sampling Time | Approx. 0.4 second |
Battery | 4 pcs size AAA (Alkaline Battery) |
Battery Life | Approx. 60 hours |
Operating Temp and Humidity | 0ºC to 40ºC (32ºF to 104ºF) below 80%RH |
Storage Temp and Humidity | -10ºC to 60ºC below 70%RH |
Weight | Approx. 165g |
Dimension | 111(L) x 64(W) x 34(H) mm |
Accessories | Operation Manual, RS-232 interface/software (1391/1392) |
Datalogging Capacity | 16000 Point Data logging (TES-1392) |
FEATURES: The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths down to 50Hz/60Hz. Display micro Tesla & milli Gauss in the same tester. Data hold, Peak hold function. RS-232 Optical inter face. (1394) 999 Datalogging capacity. | |
APPLICATIONS This EMF tester is specifically designed to determine the magnitude of electromagnetic filed radiation generated by power lines, computer's monitor, TV sets, video machinery and many other similar devices. | |
SPECIFICATION: |
Display | 3-1/2 digits. Max. indication 1999 |
Range | 20/200/2000 milli Gauss; 2/20/200 micro Tesla |
Resolution | 0.01/0.1/1 milli Gauss; 0.001/0.01/0.1 micro Tesla |
Number of Axis | Three axis |
Band Width | 30 Hz to 2000 Hz |
Accuracy | ±(3%+3d) at 50Hz or 60HZ; ±(5%+3d) at 40Hz to 200HZ; -3dB at 30Hz to 2000HZ |
Over-Input | Display shows “OL” |
Datalogger | 999 reading |
Sampling Time | Approx. 0.5 second |
Battery | 6 pcs size AAA 1.5V |
Battery Life | Approx. 100 hours |
Operating Temp and Humidity | 0ºC to 50ºC (32ºF to 122ºF) below 80%RH |
Storage Temp and Humidity | -10ºC to 60ºC below 70%RH |
Weight | Approx. 165g |
Dimension | 154(L) × 72 (W) × 35(H) mm |
Accessories Included | Operation Manual , 6 pcs size AAA, [Software for windows, RS-232 Cable (1394)]. |
FEATURES: The hand held Gauss Meter is designed to measure the magnetic field. Small size, light weight and convenient carry, have judgment function of magnetic field polarity. Specifications: Range: 0~200mT, 0~2000mT (Note: 1mT=10Gauss) Accuracy: ±2% (0~999mT); ±5% (1000~2000mT) Resolution: 0.1mT, 1mT Magnetic Field: DC Display: 3-1/2" digital display Size: 150 x 70 x 30mm Weight: 450g Power: 9V adaptor or 6 x AA battery |
FEATURES: The hand held Gauss Meter is designed to measure the magnetic field. Small size, light weight and convenient carry, have judgment function of magnetic field polarity. Specifications: Range: 0~200mT, 0~2000mT; 0~2000Gs, 0~20000Gs Accuracy: ±1% (0~100mT); ±2% (100~2000mT) Resolution: DC x 1:0.00~200.00mT 0.01mT DC×10:0.0~2000.0mT 0.1mT AC×1:0.00~200.00mT 0.01mT AC×10:0.0~2000.0mT 0.1mT Magnetic Field: AC, DC Peak Value Hold function. Gs/mT changeable. In AC shows NS polarity. Quick zero setting Display: 4-1/2" digital display Size: 150 x 70 x 30mm Weight: 450g Power: 9V adaptor or 6 x AA battery |
AE770 is a palm-sized electrostatic measuring device ideal for checking ion balance and Sensor for polarity of static charge. Features: • Measuring polarity and intensity of static charge on parts and assembly lines • Checking ion balance performance of various ionizers | |
Applications For checking the performance of ionizers, locating and measuring electrostatic charge build-up, deciding best location for installing ionizers and testing their efficiency, etc. | |
Technical Specification: Measuring range: Static voltage: ±0 ~ ±1.49 kV (Low range), ±1.0 ~ ±20.0 kV (High range) Ion balance voltage measuring range 0 ~ ±200 V Measuring distance: 25 mm ± 0.5 (between charged object and field meter) Accuracy: ±10% Ambient conditions: 10°C ~ 40°C, 68%RH or lower Display: Large LCD display (Digital and bar graph) Power: 9V, 6F22Y Weight with battery Approx. 140g without ion balance plate (Ion balance plate: Approx. 30g) |
Features: The AE-780 Surface Resistance Meter is an easy to use tester for measuring surface resistivity. This meter is designed to be used in all facets of material production including engineering, maintenance, quality control, incoming inspection, manufacturing, research, or sales departments for the testing of anti-static mats, floor finishes, paints, wrist straps, smocks, foot wear, bags and containers. When using the built-in electrodes, the meter's test values for surface resistivity are in ohms per square (although they are displayed in ohms). When using the external five pound electrodes, the meter's test values for resistance are in ohms. Specifications: Dimension: approx 70mm x 130mm x 35mm Weight: approx. 103 grams Power: Battery operated 9 volt Connections: 2 x 3.5mm jack plug for each earth connection Test Range: 103 to 1012 Dissipative Range: 3 x 105 to 3 x 109 1/2 Decade between each decade on a logarithmic scale Example: 1 x 105 x 3.21=3 x 105 (1/2 Decade Measurement) x 3.21=1x106 Method of Measurement: Surface Resistivity (Ohms per square); Point to Point Resistance (Ohms); Accuracy:- +/- 0.5 Decade in Conductive Range; +/- 0.25 Decade in Dissipative Range |
Specifications: 1. Measuring range of resistance: 103-1012Ω 2. Measuring precision of resistance: ±10% 3. Response time of resistance measurement:1S 4. Measuring range of temperature: 0ºC~50ºC/32~122ºF 5. Measuring precision of temperature:±2ºC/±3.6ºF 6. Power supply:9V 6F22 battery 7. Dimension:63.6X31X125.8mm 8. Weight:157.60g |
Features: -Quick visual display of static from 0-19,990 volts -Touch to test static in both positive and negative polarity -Easy to ground by simultaneously touching 10mm snap contact -Low battery indicator built into liquid crystal display (LCD) -Micro-power circuit allows 9-volt alkaline battery to continuously display for approximately six months -Conductive static-safe carrying case with protective anti-static foam included -Detects how much static a person is carrying -Audits any potential static generator or disspater including the following: Wrist straps, heel grounders, toe straps, static-safe shoes, chairs, table mats, floor mats, ground leads, purpose-built floors, garments, static sprays, floor finishes, the difference in potential between two people or materials, etc. Specifications: Power Supply: 9volt alkaline battery Battery Life: Approximately six months Operating Voltage: >6.5 volts. 9 volts; Low bat set at 6.5 volts Temperature Range: Operation 40ºF to 120ºF (5ºC to 49ºC) Storage: 40ºF to 95ºF (5ºC to 35ºC) Relative Humidity: 0% to 90% (non-condensing) Accuracy: ±5% Weight: 230g |
Features: The AE-800 Megohmmeter kit measures surface resistivity, resistance, temperature and humidity. It is designed to test conductive, anti-static, and static dissipative surfaces for electrical resistivity/resistance according to EOS/ESD, CECC, ANSI, ASTM and UL test procedures. The internal parallel electrodes comply with DIN EN 100 015/1 & ANSI/ESDA-S11.11. The five pound electrodes can be externally connected for tests according to IEC 61340-4-1, ANSI/ESDA S4.1 & ANSI/ESDA S7.1. Specifications: Resistivity: 103 ~1012 ohms/sq Resistance: 103 ~1012 ohms Relative Humidity: 10% - 90% RH Temperature: 32ºF ~ 100ºF or 0ºC ~ 37.7ºC if Celsius model was purchased Measuring voltage: 10v and 100v |
Features: The RT-1000 Resistance, resistivity ,temperature, humidity Test kit is easy to operate, compact, lightweight, portable meter designed to measure temperature, humidity and electrical resistivity/resistance. Using both internal and external test probes, the meter will measure resistivity, resistance to ground, resistance between two points according to EOS/ ESD association standards- S4.1, S6.1, S7.1, S11.11 and European standard CECC-EN 1000/15. With the accessory probes the meter can test the electrical circuitry of the building, ESD chairs, and smocks. Additional probes are available to measure heel straps, wrist straps, and small parts using miniature probes, and a concentric ring probe. Specifications: 1. Resistivity Test Ranges: 1 x 103 – 9 x 106 ohms @10volts; 1 x 106 – 9 x 1012 ohms @100 volts 2. Dimensions: 7.50 inch (19.05cm)L x 4.00 inch (10.16 cm) W x 1.5 inch (3.81cm) H. 3. Current Limit: 1 milliamp DC current for 10 volts; 0.1 milliamp DC current for 100 volts. 4. Accuracy: 103~108 ohms +/-10%; 109~1010 ohms +/-15%; 1011~1012 ohms +/-25% 5. Zero: Automatic zeroing 6. Operating Conditions: 32°F-100°F (0~38°C) |
Features: 1. To test the wrist strap if it is well grounded 2. To test the resistance between the wrist strap and user's wrist 3. Easy to operate, uses 9V dry battery Technical Data: 1. Power Source: 9V dry battery 2. Grounding Clip: 2.5m 3. Dimensions: 80 x 40 x 117mm | |||
Resistance | LED Indicator | Beeper | |
R < 800K ohm | Red (LOW) | No beep | |
800K ohm≦ R ≦ 9M ohm | Green (GOOD) | Beep | |
R > 9M ohm | Red (HIGH) | No beep |
Features: The Charge Plate Monitor CPM-374 with its built-in timer function consists of a high voltage unit and an electrostatic field meter. Therefore it has an input resistance of 1016W and is suited for measuring static potentials and discharging times of air ionizers. The CPM-374 corresponds to DIN EN 61340-5-1 and EOS/ESD S.3.1. Specifications: 1. Dimensions (L x W x H): 152 x 152 x 152mm 2. Weight: Approx. 1.5kg 3. Display: Alpha-numeric display (100mm x 24mm), 2 lines with 16 digits each 4. Measurement ranges: 1) Charge Plate: Voltage potentials up to ±1000V; 2) Voltmeter (MK11): Voltages up to ±2000V; 3)Static field meter: El. DC fields up to ±200kV/m 5. PC-Interface: Serial port, 9-pol. Sub-D connector 6. Battery: 7.2V / 1300mAh 7. Time of operation: Approx. 4h on continuous duty with fully charged battery 8. Charging time: Max. 14h 9. Wall power supply: Prim. 230V / 50Hz, sec. 12V DC / 750mA 10. Current consumption: Max. 600mA, battery powered max. 150mA 11. Temperature range: 0…40°C 12. Humidity: 10…60% humidity |
CHARGED PLATE/PROBE ASSEMBLY: 1. Designed to EOS/ESD Association standard 2. Standard tripod mount 3. Dimensions: 6” X 6” 4. Capacitance: Total discharge test circuit with plate 20 picofarads, ±2 picofarads 5. Plate self-discharge: Less than 10% of set voltage within 5 minutes below 50% RH at 25°C POWER SUPPLY: ±7500 volts maximum output; ±1000 volts/±5000 volts charging of isolated plate available, adjustable from <±1000 to >±5000 volts ELECTROSTATIC FIELD METER: RANGE: 0 to ±7500 volts; 0 to ±2000 volts—switch selectable ACCURACY: Better than 2% DRIFT: Less than 0.4% per hour non-cumulative after 10 minutes stabilization, typical SPEED OF RESPONSE: Less than 100ms for 10% to 90% of full scale either range OUTPUT: Divide input by 1000, impedance 100Ω TIMER: Full scale 999.9 sec. (>16 min.), 0.1 sec. Resolution POWER REQUIREMENTS: 117 or 220 volts ±10% (factory preset), 50/60 Hz, 5 watts SIZE AND WEIGHT: Height 6¾”, Width 6¾”, Depth 9½”; 5.5 lbs. (17 x 17 x 24 cm, 2.3kg) |
Features: Simple and easy to test the home, office, warehouse, shcool electromagnetic radiation value for health protection. With external probe so that can test from all directions and response fast. Specifications: Range: 0-1999 (v/m for low frequency or uw/cm2 for high frequency, if more than 1999 it will display 1---) Sampling time: 0.4s Frequency Range: 50Hz ~ 2000MHz (2GHz) Power: 9V (6F22) Size: 132 x 69 x 29mm Weight: 190g Note: Safety value suggest 40 max according to China government standard. 1000MHz=1000Hz; 1GHz=1000MHz. Low frequency Range: 30Hz ~ 300Hz; Medium frequency: 300Hz ~ 3MHZ; High frequency: 3MHz~30MHz. For most home and office appliance between range 50~2000MHz. |
Voltmeter of internal battery resistance is mainly used to measure battery terminal voltage and internal resistance. The internal resistance is measured with the international standard AC signal (1000Hz±10%) by means of four-wire method to ensure the impact of the test probe of the contact resistance of the instrument, the wire and battery output terminal on the measured value, and the battery voltage can also be measured at the same time. It is applicable for measurement of internal resistances of Lithium-ion, nickel-hydroxide, lithium-manganese, lead-acid and other single cell or all kinds of assembled battery. Specifications: 3-1/2 digits 18mm LCD Voltage Measurement Range: 0~1.999V, 2~19.99V, 20~199.9V Voltage resolution: (0~1.999V)1mV, (2~19.99V)10mV, (20~100V)100mV Internal Resistance Range: 0~199.9mΩ, 200~1,999mΩ, 2~19.99Ω Internal Resistance Resolution:(0~199.9mΩ)0.1mΩ, (200~1,999mΩ)1mΩ, (2~19.99Ω)10mΩ |
The meter can inspect particular objects or devices radiate low frequency electromagnetic waves. It can use for power wire, computer monitor, TV, audio and visual, electromagnetic oven oven or analogous electrical installation. Measuring range: 0.1-400mG,1-4000mG 0.01-40uT,0.1-400uT Accuracy:±(3%rdg+3digits)50Hz/60Hz Proper frequency:30Hz-400Hz Exceed measuring range: LCD will display "OL" Sampling time:0.5 second Power: one 9V battery (model 6F22) Operating environment: Temperature: 0-50℃(32-122°F) Relative humidity: ≤80%RH Dimensions: 138L×71W×35H(mm) |
The meter is using for detecting high frequency radiation from 50MHz to 3.5GHz,it has all-aspect electric field's test and high sensitivity. It can use for measuring the electric field strength and magnetic field strength of TEM cells and absorber rooms. The meter can display the instantaneous measurement value, the MAX measurement value and average measurement value. The instantaneous measurement value can use for directional measurement, for example: when you go to the exposed zone first. Metrical ways: digit display, measuring with three axes Characteristic of directivity: all-aspect,three axes Resolutin displayed:0.1mV/m,0.1uA/m,0.1uW/M2 Reaction time: about 1 second (the measurement value is from 0 to 90%) Refresh rate displayed: about 0.5 second Display format:LCD,4 digits Alarm: buzzer Units: mV/m, V/m, u A/m, m A/m, u W/m2,mW/m2,uW/cm2 Displayed value :the instantaneous measurement value, the MAX measurement value, average measurement value and the maximum averaging value Warning function: you can adjust the setting value and you also can open the function or close it. Manual memory and reading data content:99 groupsUSB Interface Data Logger Power:4×1.5V AA battery Operating environment: Temperature: 0-50℃(32-122°F) Relative humidity: ≤80%RH Dimensions and weight: 261L×73W×38H(mm) |
Model | AMF047 | AMF048 | AMF049 | AMF050 |
Power Supply | 220V 50HZ; Max 10A (Within 2.2KW) | 220V 50HZ; Max 1A (Within 220W) | 220V 50HZ; Max 10A (Within 2.2KW) | 220V 50HZ; Max 16A (Within 3.5KW) |
Time Switch | NO | NO | Yes | NO |
Clock Display | NO | NO | Yes | NO |
Buzzer Alarm | NO | NO | Yes | NO |
Over Current Protection | NO | NO | Yes | NO |
Accuracy | 1.0 | |||
Constant | 6400imp/KWH | |||
Power Dissipation | <1W | |||
Operating Temperature | 0~45°C | |||
Storage Temperature | -20~60°C | |||
Monitoring Current Value | Yes | |||
Active Power | Yes | |||
Monitoring Current Voltage, Current, Frequency | Yes | |||
Record of Total Time Consumption | Yes | |||
Record of Total Electricity Consumption | Yes | |||
Calculate CO2 Emissions | Yes | |||
Power Factor Detection | Yes | |||
Set Alarm Threshold Load | Yes | |||
Large LCD Display | Yes |
MODEL | HY3002D | HY3003D | HY3005D | |
Input Voltage | 110/220V±10% | |||
Output Voltage | 0 ~ 30V | |||
Output Current | 0 ~2A | 0 ~ 3A | 0 ~ 5A | |
Source Effect | CV ≤ 0.01%±1mV; CC ≤ 0.02%±1mA | |||
Load Effect | CV ≤ 0.01%±5mV; CC ≤ 0.02%±5mA | |||
Ripple & Noise | ≤ 1mVrms | |||
Display | Two 3 1/2 digit LCD display | |||
Accuracy | V: ±1%±2digits; C: ±2%±2digits | |||
Size | 291 × 158 × 136mm | |||
Weight | 3 ~ 6kg |
MODEL | HY3002 | HY3003 | HY3005 | HY5002 | HY5003 | |
Input Voltage | 110/220V±10%AC | |||||
Output Voltage | 0 ~ 30V | 0 ~ 50V | ||||
Output Current | 0 ~ 2A | 0 ~ 3A | 0 ~ 5A | 0 ~ 2A | 0 ~ 3A | |
Source Effect | CV≤ 0.01%±1mV; CC≤ 0.01%±1mA | |||||
Load Effect | ≤ 0.01%±5mV | ≤ 0.01%±15mV | ||||
Ripple & Noise | ≤ 1mVrms | |||||
Display | Two 3 1/2 digit LED display | |||||
Accuracy | V: ±1%±2digits C: ±1.5%±2digits | |||||
Size | 291 × 158 × 136mm | |||||
Weight | 3 ~ 6kg |
MODEL | HY1502D | HY1503D | HY1802D | HY1803D | |
Input Voltage | 110/220V±10%AC | ||||
Output Voltage | 0~15V | 0~18V | |||
Output Current | 0~2A | 0~3A | 0~2A | 0~3A | |
Source Effect | CV≤0.01%±1mV; CC≤0.02%±1mA | ||||
Load Effect | CV≤0.01%±5mV; CC≤0.02%±5mA | ||||
Ripple & Noise | ≤1mVrms | ||||
Display | Two 3 1/2 digit LCD display | ||||
Accuracy | V: ±1%±2digits; C: ±2%±2digits | ||||
Size | 206×153×110mm | ||||
Weight | 3~4.5kg |
MODEL | HY3010 | HY3020 | |
Input Voltage | 110/220V±10%AC | ||
Output Voltage | 0~30V | ||
Output Current | 0~10A | 0~20A | |
Source Effect | ≤0.02%±3mV | ||
Load Effect | ≤0.01%±10mV | ≤0.02%±25mV | |
Ripple & Noise | ≤3mVrms | ||
Display | Two 3 1/2 digit LED display | ||
Accuracy | V: ±1%±2digits; C: ±2%±2digits | ||
Size | 365×265×164mm | ||
Weight | 10~20kg |
MODEL | HY3002D-2 | HY3003D-2 | HY3005D-2 | |
Input Voltage | 110/220V ± 10%AC | |||
Output Voltage | 2×0 ~ 30V | |||
Output Current | 2×0 ~ 2A | 2×0 ~ 3A | 2×0 ~5A | |
Source Effect | CV ≤ 0.01% ± 1mV; CC ≤ 0.02% ± 1mA | |||
Load Effect | CV ≤ 0.01% ± 5mV; CC ≤ 0.02% ± 5mA | |||
Ripple & Noise | ≤ 1mVrms | |||
Display | Four 3 1/2 digit LCD display | |||
Accuracy | V: ± 1% ± 2digits; C: ± 2% ± 2digits | |||
Size | 365×265×164mm | |||
Weight | 8 ~ 12kg |
MODEL | HY3002-2 | HY3003-2 | HY3005-2 | HY5002-2 | HY5003-2 | |
Input Voltage | 110/220V ± 10%AC | |||||
Output Voltage | 2×0 ~ 30V | 2×0 ~ 50V | ||||
Output Current | 2×0 ~ 2A | 2×0 ~ 3A | 2×0 ~ 5A | 2×0 ~ 2A | 2×0 ~ 3A | |
Source Effect | CV ≤ 0.01% ± 1mV; CC ≤ 0.01% ± 1mA | |||||
Load Effect | ≤ 0.01% ± 5mV | ≤ 0.01% ± 15mV | ||||
Ripple & Noise | ≤ 1mVrms | |||||
Display | Two 3 1/2 digit LED display | |||||
Accuracy | V: ±1% ± 2digits C: ± 2% ± 2digits | |||||
Size | 365×265×164mm | |||||
Weight | 8 ~ 12kg |
MODEL | HY3002D-3 | HY3003D-3 | HY3005D-3 | |
Input Voltage | 110/220V±10%AC | |||
Output Voltage | 2×0~30V | |||
Output Current | 2×0~2A | 2×0~3A | 2×0~5A | |
Source Effect | CV≤0.01%±1mV; CC≤0.02%±1mA | |||
Load Effect | CV≤0.01%±5mV; CC≤0.02%±5mA | |||
Ripple & Noise | ≤1mVrms | |||
Fixed Output | 5V/3A | |||
Display | Four 3 1/2 digit LCD display | |||
Accuracy | V: ±1%±2digits; C: ±2%±2digits | |||
Size | 365×265×164mm | |||
Weight | 8~12kg |
MODEL | HY3002-3 | HY3003-3 | HY3005-3 | |
Input Voltage | 110/220V±10%AC | |||
Output Voltage | 0~30V | |||
Output Current | 2×0~2A | 2×0~3A | 2×0~5A | |
Source Effect | CV≤0.01%±1mV; CC≤0.02%±1mA | |||
Load Effect | CV≤0.01%±5mV; CC≤0.02%±5mA | |||
Ripple & Noise | ≤1mVrms | |||
Fixed Output | 5V/3A | |||
Display | Two 3 1/2 digit LED display | |||
Accuracy | V: ±1%±2digits; C: ±2%±2digits | |||
Size | 365×265×164mm | |||
Weight | 8~13kg |
The digital control DC power supply have the excellent capabilities, such as convenient numeric input keypad, large LCD screen, intuitionistic voltage/current display, V/I adjust step by step, memory keys to store your voltage used frequently and recall it easily. It can be widely used in laboratories, factories, universities and so on. | |||
Features: ● Liner digital control DC power supply ● Convenient keyboard V/I input ● Fine V/I tuning by stepping potentiometer ● Colorful LCD screen ● Intellective fan cooling ● Low noise and ripple output ● Voltage and current memory function ● Over current and temperature protection ● CV / CC mode | |||
Specifications: | |||
Input voltage | 110V AC±10% 50Hz ±2% or 220V AC±10% 50Hz ±2% | ||
Input power | 160~ 250VA | ||
Rated Output | DP3003 | DP3005 | |
Voltage | 0 ~ 30V | 0 ~ 30V | |
Current | 0 ~ 3A | 0 ~ 5A | |
Line regulation ±% of Output + offset | Voltage | CV≤0.01%+3mV | |
Current | CC≤0.05%+5mA | ||
Load regulation ±% of Output + offset | Voltage | CV≤0.01%+3mV | |
Current | CC≤0.05%+5mA | ||
Set accuracy 25ºC ±% of Output + offset | Voltage | ≤0.1%+10mV | |
Current | ≤0.1%+10mA | ||
Read back resolution | Voltage | 10mV,1mV | |
Current | 10mA,1mA | ||
Measure accuracy 25ºC ±% of Output + offset | Voltage | ≤0.05%+5mV | |
Current | ≤0.05%+5mA | ||
Measure speed | Voltage | 160ms/ones | |
Current | 160ms/ones | ||
ripple 20 ~ 20MHz | Voltage | ≤1mVrms/3mV(P-P) | |
Current | ≤0.05%+5mA | ||
Temperature coefficient | Voltage | ≤0.05%+10mV | |
Current | ≤0.1%+10mA |